Other Accessories
(page 2 of 2)



Flexible connecting hose
Nylon lined with knurled handwheels. The hose has a standard copper wire wound spirally under the reinforcing layers of hose to electrically connect the two ¼" NPT female connectors.

407A025 Stainless Steel connectors, 24"
407A026 Brass connectors, 24"

 


Reid Vapor Pressure Gauges
Large dial (4 ½") for precise reading and repeatability. Brass ¼" IPS male thread fitting to attach to bomb. Bronze Bourdon tube, recalibrating screw and carrying handle. Conforms to ASTM D323 and D1267.

Model Number Range PSI Figure Interval Div. PSI

407A028

0-15 1 0.1
407A029 0-30 2 0.2
407A030 0-45 3 0.2
407A031 0-60 4 0.25
407A032 0-100 5 0.5
407A033 0-250 10 1
407A034 0-300 10 1
407A035 0-600 20 2

 

 


Reid Vapor Pressure Bomb Bath
Stainless steel Construction with top rim for flush mounting. Separate support for thermometer and mercury type thermoregulator preset to 100 F. Copper clad 500W immersion heater. Used in the determination of vapor pressure of gasoline, volatile crude oil liquefied petroleum gases and other volatile petroleum products. Conforms to ASTM D323, and D1267. Dimensions: 18 ¼" dia. 40 ½" OAH. Weight 60 lbs.

407A037 Three bomb capacity
407A038 Five bomb capacity

 


Sample Bombs
Sample cylinders are manufactured in accordance with D.O.T. specifications. The cylinders are designed for safe, reliable containment of gas or liquid samples during drawing, storage and handling or transport per D.O.T. regulations. Constructed of 304 stainless steel, with female pipe threads in each end.

407B039 150ml
407B040 300ml
407B041 500ml
407B042 600ml*
407B043 1000ml

 

 


Corrosion Test Bomb
For conducting the test for copper strip corrosion by liquefied petroleum (LP) gases according to ASTM D1838. Constructed of stainless steel, with two ¼" needle valves and knurled threaded cap with "O" ring seal.

407A044 Corrosion test bomb. For connecting hose see 407A025

Copper strip, to be used with 407A044 corrosion test bomb. The strip is smooth ready for final polishing and cleaning. It is ½" x 3" x 1/8" with a hole on the end for hanging in the bomb.

407A045 Copper Strip

 

 


Cylinder, hydrometer LPG
To determine the specific gravity of liquefied petroleum gases, (LPG), such as propane and butane and other light hydrocarbons under vapor pressure conditions corresponding to the temperature of the liquid. The cylinder is constructed of a transparent plastic barrel held between aluminum end plates with tie-rods. Working pressure is 200 psi and a relief valve is attached and set for this pressure. Conforms to ASTM - D1657 and GPA2140. For specific gravity hydrometers see the hydrometer section of the catalog.

407B046 Cylinder, Hydrometer complete
407B047 Cylinder, plastic barrel, replacement
407B048 Gasket, pressure
407B093 Hydrometer, LPG (see Hydrometers)

 


Flash Point Tester
Pensky - Martens

For determination of flash point of fuel oils, lube oils, suspensions of solids and other liquids according to ASTM D93. Equipped with a 750 watt heating element and heat control with reference dial. Operates on 120 volts A.C. Thermometer not included. For thermometers see 405A267, P-M low ASTM 9F and 405A269, P-M high ASTM 10F. Dimensions: 11" x 7" x 18" high. Wt. 38 lbs.

407A049 Flash Point Tester, Tag Closed Cup.

 


Flash Point Tester Tag Closed Cup
For determination of flash points of liquids below 175 F , according to ASTM D56. Complete with water bath, cover assembly with tag closed cup flashing mechanism, two thermometer wells, test flame gauge, cup, orfice, 150 watt heater and reference dial for temperature adjustments. Operates on 120 volt A.C. Thermometers not included. For thermometers see 405A267, ASTM 9F, and 405A336, ASTM 57F Dimensions, 5" x 10". Wt. 7 lbs.

407A050 Flash Point Tester, Tag Closed Cup

 

Flash Point Tester Cleveland Open Cup
For determination of flash and fire points of all petroleum products except fuel oils and those having an open cup flash point below 175 F., according to ASTM D92. Equipped with 750 watt heating element, stepless control, adjustable test flame and flash cup., Thermometer not included. For thermometer see 405A271, ASTM 11F. Operates on 120 volts A.C. Dimensions, 11" x 6" x 15". Wt. 21 lbs.

407A051 Flash Point Tester, Cleveland Open Cup

 

 

click here for page 1


2000 Bill Poole Products